Get the DuroMax XP12000EH if:
- You need CARB: the XP12000EH manual lists EPA/CARB compliance.
- 9,500W running on gas (9,025W on propane) covers your load.
- You want it a little lighter: 224 lb dry against 234 lb.
Dual fuel portable generators
The short answer
Our pick: DuroMax XP13000EH
1,000W more on gasoline (13,000 / 10,500W) and about 1,000W more on propane, from a 500cc engine, and DuroMax lists a CO shutdown on it. The XP12000EH is the pick if you need CARB: its manual lists EPA/CARB compliance, while DuroMax lists the XP13000EH as not CARB.
Best if you need CARB
Best for more power
Before you buy: Both listings sit in one style family (5,500 to 13,000 watts, gas and dual fuel); make sure you land on "12,000-Watt Dual Fuel" or "13,000-Watt Dual Fuel". The XP13000EH is sold by Amazon, but when we checked in mid-October, Amazon listed delivery as November 12 to December 24, so check the delivery date before you order. Still check the seller, since the featured offer can change. Both are open-frame (not inverter) generators and non-returnable (hazmat).
As an Amazon Associate I earn from qualifying purchases.
Counted from the chart below: rows where one figure is clearly better. It's a tally, not an overall rating. The 1/4-load run time isn't counted: 1/4 load on the XP12000EH is fewer watts than on the XP13000EH. The CO row counts for the XP13000EH because only its maker lists one.
A green check means one figure is clearly better. No check means it's a tie, it's close, the makers measured it differently, or a figure is Unknown. Maker figures are used throughout; anything marked Amazon only comes from the Amazon listing, not the maker.
| XP12000EH | XP13000EH | Clearer | |
|---|---|---|---|
| Starting / running watts (gasoline) | 12,000 / 9,500W | 13,000 / 10,500W | XP13000EH |
| Starting / running watts (propane) | 11,400 / 9,025W | 12,500 / 10,000W | XP13000EH |
| Fuel | Gasoline + propane (hose and regulator included) | Gasoline + propane (hose and regulator included) | |
| Engine | 457cc OHV, carbureted | 500cc OHV, carbureted | |
| Gas tank | 8.3 gal | 8.3 gal | |
| Run time, gasoline 1/4 / 1/2 load | 19 hr / 8 hr | 17 hr / 8 hr | |
| Run time, propane 1/4 / 1/2 load | 14 hr / 7 hr (manual: 7 hr on a 40 lb tank) | 13 hr / 6 hr (tank not stated) | |
| Noise (distance and load not stated) | 74 dB | 74 dB | |
| 120V outlets | 2x 5-20R (GFCI), 1x L5-30R | 2x 5-20R (GFCI), 1x L5-30R | |
| 240V outlets | 1x L14-30R, 1x 14-50R (50A) | 1x L14-30R, 1x 14-50R (50A) | |
| 12V | 12V DC listed (DC charging cables included); outlet type Unknown | 12V automotive outlet | |
| THD | Unknown | Unknown | |
| Parallel | Unknown | Unknown | |
| CO shutoff | Unknown on maker sources; Amazon only: "CO Alert" shutdown | Yes (maker) | XP13000EH |
| Start | Electric (key) + recoil; battery included | Push-button electric + recoil; battery included | |
| Neutral | Floating | Unknown | |
| Weight (dry) | 224 lb | 234 lb | |
| Size (L x W x H) | 29 x 30 x 26 in | 29 x 30 x 26 in | |
| EPA / CARB | EPA/CARB (owner's manual) | EPA certified; not CARB, not 50-state | XP12000EH |
| Warranty | 3 years | 3 years |
Common things people plug in during an outage or at camp, checked against each generator's own gasoline ratings from the chart above: XP12000EH 9,500W running and 12,000W starting, XP13000EH 10,500W running and 13,000W starting. I used the top of each range, so a smaller appliance may do better. These are estimates, not test results.
| Load | Running watts | Starting watts | XP12000EH | XP13000EH |
|---|---|---|---|---|
| Full-size refrigerator | 150–400W | 800–1,200W | Yes | Yes |
| Freezer (chest or upright) | 100–500W | 500–1,000W | Yes | Yes |
| Sump pump, 1/3 HP | 500–800W | 1,000–1,600W | Yes | Yes |
| Sump pump, 1/2 HP | 800–1,050W | 1,300–2,150W | Yes | Yes |
| Gas furnace blower (1/2 HP fan) | 300–800W | 800–1,600W | Yes | Yes |
| Window AC, 5,000 BTU | 450–600W | 900–1,200W | Yes | Yes |
| Window AC, 10,000 BTU | 900–1,200W | 1,800–2,400W | Yes | Yes |
| RV rooftop AC, 13,500 BTU | 1,500–2,000W | 2,800–3,500W | Yes | Yes |
| CPAP (with heated humidifier) | 60–120W | No extra | Yes | Yes |
| Microwave | 600–1,200W | No extra | Yes | Yes |
| Coffee maker | 600–1,200W | No extra | Yes | Yes |
| Space heater (1,500W setting) | 750–1,500W | No extra | Yes | Yes |
| Well pump, 1 HP‡ | 1,000–2,000W | 2,000–4,000W | Yes | Yes |
| Circular saw, 7-1/4 in. | 1,200–1,800W | 2,400–3,600W | Yes | Yes |
| TV (32-55 in.) + router/modem | 90–420W | No extra | Yes | Yes |
| Phone/laptop charging | 20–100W | No extra | Yes | Yes |
| Electric water heater‡ | 3,000–4,500W | No extra | Yes | Yes |
‡ Both list L14-30R and 14-50R 240V outlets, so 240V well pumps and water heaters are on the table. Hooking a generator to house wiring needs a transfer switch or interlock.
Add up the running watts. Then take the one item with the biggest starting surge and add its starting watts to everything else's running watts. Both totals have to fit. Estimates.
Running: 400 + 800 + 75 + 20 = 1,295W (XP12000EH 14% of 9,500W · XP13000EH 12% of 10,500W)
Biggest start: fridge starting 1,200 + everything else running 800 + 75 + 20 = 2,095W (XP12000EH 17% of 12,000W · XP13000EH 16% of 13,000W)
XP12000EH YesXP13000EH Yes
Running: 400 + 500 + 1,050 + 75 + 20 = 2,045W (XP12000EH 22% of 9,500W · XP13000EH 19% of 10,500W)
Biggest start: 1/2 HP sump pump starting 2,150 + everything else running 400 + 500 + 75 + 20 = 3,145W (XP12000EH 26% of 12,000W · XP13000EH 24% of 13,000W)
XP12000EH YesXP13000EH Yes
Running: 2,000 + 600 + 150 + 100 = 2,850W (XP12000EH 30% of 9,500W · XP13000EH 27% of 10,500W)
Biggest start: 13,500 BTU AC starting 3,500 + everything else running 600 + 150 + 100 = 4,350W (XP12000EH 36% of 12,000W · XP13000EH 33% of 13,000W)
XP12000EH YesXP13000EH Yes
These are typical figures. Check the label on your own appliance. It lists watts, or amps you can multiply by 120 to get watts.
Motors need starting watts. Fridges, freezers, pumps, furnace blowers and air conditioners pull a short surge each time they kick on, well above their running watts. Heaters, coffee makers and chargers don't.
Running several loads adds up. If two motors start in the same second, both surges stack. Start the big ones one at a time.
Load watts: Champion Power Equipment, Generator Wattage Chart. It covers appliances, not generators. Coffee maker range from Honda's wattage guide.
Both burn gasoline or propane, so both put out carbon monoxide. Keep them outside, well away from doors, windows and vents. DuroMax lists a CO sensor shutdown on the XP13000EH; for the XP12000EH only the Amazon listing mentions one. Either way, it's a backup, not a reason to run one in a garage.
Same tank, same frame size, same outlet panel. Pick by power and CARB.
As an Amazon Associate I earn from qualifying purchases.
if you want a CO shutdown listed by the maker. DuroMax's pages read for this page don't list one; only the Amazon listing does.
if you live in California. DuroMax lists it as not CARB and not 50-state.
Where the maker and the Amazon listing (or two maker documents) give different figures. This page uses the maker figure unless noted.
The XP13000EH: 13,000W peak and 10,500W running on gas, against 12,000 / 9,500W.
Its owner's manual lists EPA/CARB compliance. The current DuroMax product page couldn't be opened to confirm it.
DuroMax lists 19 hr at 1/4 load for the XP12000EH and 17 hr for the XP13000EH, on the same 8.3 gal tank. 1/4 load is fewer watts on the smaller unit, so it isn't like-for-like. At 1/2 load both list 8 hr on gas.
DuroMax doesn't list parallel capability for either.
By Mike E. · Last checked October 16, 2026 · Based on manufacturer specs. Lines marked "Amazon only" are from Amazon, not the maker.