Get the DuroMax XP13000EH if:
- You want a 12V automotive outlet. DuroMax lists one on the EH and not the HX.
- You'd rather buy from Amazon.com itself. The linked EH is sold and shipped by Amazon.
- Two 120V household outlets are enough for you.
Dual fuel portable generators
The short answer
Our pick: DuroMax XP13000HX
Same watts, engine, tank and noise figure. The HX wins on the two things that differ: four GFCI 5-20R outlets instead of two, and a 5-year warranty instead of 3.
Best if you want a 12V outlet
Best for whole-home backup
Before you buy: These are open-frame (not inverter) generators at about 240 lb. Neither is CARB compliant, so neither is 50-state. The EH listing is sold by Amazon.com; the HX listing is sold by a third-party seller. Both are non-returnable (hazmat).
As an Amazon Associate I earn from qualifying purchases.
Counted from the chart below: rows where one figure is clearly better. It's a tally, not an overall rating. The EH's 12V outlet and 6 lb weight edge are real but small, so they aren't counted as wins.
A green check means one figure is clearly better. No check means it's a tie, it's close, the makers measured it differently, or a figure is Unknown. Maker figures are used throughout; anything marked Amazon only comes from the Amazon listing, not the maker.
| XP13000EH | XP13000HX | Clearer | |
|---|---|---|---|
| Starting / running watts (gasoline) | 13,000 / 10,500W | 13,000 / 10,500W | |
| Starting / running watts (propane) | 12,500 / 10,000W | 12,500 / 10,000W | |
| Fuel | Gasoline + propane (hose and regulator included) | Gasoline + propane (4 ft hose and regulator included) | |
| Engine | DuroMax 500cc OHV, carbureted | DuroMax 500cc OHV, carbureted | |
| Gas tank | 8.3 gal | 8.3 gal | |
| Run time, gasoline 1/4 / 1/2 load | 17 hr / 8 hr | 17 hr / 8.5 hr | |
| Run time, propane 1/4 / 1/2 load (tank not stated) | 13 hr / 6 hr | 13 hr / 6.5 hr | |
| Noise (distance and load not stated) | 74 dB | 74 dB | |
| 120V outlets | 2x 5-20R (GFCI), 1x L5-30R | 4x 5-20R (GFCI), 1x L5-30R | XP13000HX |
| 240V outlets | 1x L14-30R, 1x 14-50R (50A) | 1x L14-30R, 1x 14-50R (50A) | |
| 12V outlet | Yes, 12V automotive | Not listed | |
| TT-30R | No | No | |
| THD | Unknown | Under 5% | |
| Parallel | Unknown | Unknown | |
| CO shutoff | Yes | Yes | |
| Start | Push-button electric + recoil; battery included; no remote | Push-button electric + recoil; battery included; no remote | |
| Idle control | No-load low idle | No-load low idle | |
| Display | Volt meter, hour meter, fuel gauge | Volt meter, hour meter, fuel gauge | |
| Weight (dry) | 234 lb | 240 lb | |
| Size (L x W x H) | 29 x 30 x 26 in | 30 x 29 x 26 in | |
| EPA / CARB | EPA certified; not CARB | EPA certified; not CARB | |
| Warranty | 3 years | 5 years | XP13000HX |
Common things people plug in during an outage or at camp, checked against each generator's own gasoline ratings from the chart above: XP13000EH 10,500W running and 13,000W starting, XP13000HX 10,500W running and 13,000W starting. I used the top of each range, so a smaller appliance may do better. These are estimates, not test results.
| Load | Running watts | Starting watts | XP13000EH | XP13000HX |
|---|---|---|---|---|
| Full-size refrigerator | 150–400W | 800–1,200W | Yes | Yes |
| Freezer (chest or upright) | 100–500W | 500–1,000W | Yes | Yes |
| Sump pump, 1/3 HP | 500–800W | 1,000–1,600W | Yes | Yes |
| Sump pump, 1/2 HP | 800–1,050W | 1,300–2,150W | Yes | Yes |
| Gas furnace blower (1/2 HP fan) | 300–800W | 800–1,600W | Yes | Yes |
| Window AC, 5,000 BTU | 450–600W | 900–1,200W | Yes | Yes |
| Window AC, 10,000 BTU | 900–1,200W | 1,800–2,400W | Yes | Yes |
| RV rooftop AC, 13,500 BTU | 1,500–2,000W | 2,800–3,500W | Yes | Yes |
| CPAP (with heated humidifier) | 60–120W | No extra | Yes | Yes |
| Microwave | 600–1,200W | No extra | Yes | Yes |
| Coffee maker | 600–1,200W | No extra | Yes | Yes |
| Space heater (1,500W setting) | 750–1,500W | No extra | Yes | Yes |
| Well pump, 1 HP‡ | 1,000–2,000W | 2,000–4,000W | Yes | Yes |
| Circular saw, 7-1/4 in. | 1,200–1,800W | 2,400–3,600W | Yes | Yes |
| TV (32-55 in.) + router/modem | 90–420W | No extra | Yes | Yes |
| Phone/laptop charging | 20–100W | No extra | Yes | Yes |
| Electric water heater‡ | 3,000–4,500W | No extra | Yes | Yes |
‡ Both list L14-30R and 14-50R 240V outlets, so 240V well pumps and water heaters are on the table. Hooking a generator to house wiring needs a transfer switch or interlock.
Add up the running watts. Then take the one item with the biggest starting surge and add its starting watts to everything else's running watts. Both totals have to fit. Estimates.
Running: 400 + 800 + 75 + 20 = 1,295W (XP13000EH 12% of 10,500W · XP13000HX 12% of 10,500W)
Biggest start: fridge starting 1,200 + everything else running 800 + 75 + 20 = 2,095W (XP13000EH 16% of 13,000W · XP13000HX 16% of 13,000W)
XP13000EH YesXP13000HX Yes
Running: 400 + 500 + 1,050 + 75 + 20 = 2,045W (XP13000EH 19% of 10,500W · XP13000HX 19% of 10,500W)
Biggest start: 1/2 HP sump pump starting 2,150 + everything else running 400 + 500 + 75 + 20 = 3,145W (XP13000EH 24% of 13,000W · XP13000HX 24% of 13,000W)
XP13000EH YesXP13000HX Yes
Running: 2,000 + 600 + 150 + 100 = 2,850W (XP13000EH 27% of 10,500W · XP13000HX 27% of 10,500W)
Biggest start: 13,500 BTU AC starting 3,500 + everything else running 600 + 150 + 100 = 4,350W (XP13000EH 33% of 13,000W · XP13000HX 33% of 13,000W)
XP13000EH YesXP13000HX Yes
These are typical figures. Check the label on your own appliance. It lists watts, or amps you can multiply by 120 to get watts.
Motors need starting watts. Fridges, freezers, pumps, furnace blowers and air conditioners pull a short surge each time they kick on, well above their running watts. Heaters, coffee makers and chargers don't.
Running several loads adds up. If two motors start in the same second, both surges stack. Start the big ones one at a time.
Load watts: Champion Power Equipment, Generator Wattage Chart. It covers appliances, not generators. Coffee maker range from Honda's wattage guide.
Both burn gasoline or propane, so both put out carbon monoxide. Keep them outside, well away from doors, windows and vents. Both list a CO shutdown, but it's a backup, not a reason to run one in a garage.
These are the same generator in two outlet layouts. Pick by outlets and warranty, not by power.
As an Amazon Associate I earn from qualifying purchases.
if you want the longer warranty or more household outlets. It has 3 years and two GFCI 5-20R outlets.
if you need a 12V outlet. DuroMax doesn't list one on the HX.
Where the maker and the Amazon listing (or two maker documents) give different figures. This page uses the maker figure unless noted.
Yes. DuroMax lists both at 13,000W starting and 10,500W running on gasoline, and 12,500W / 10,000W on propane.
On watts, either covers a lot: both have L14-30R and 14-50R 240V outlets. You still need a transfer switch or interlock to connect to house wiring.
DuroMax lists 13 hr at 1/4 load on propane but doesn't say what tank size that is based on. It suggests a 40 lb tank minimum.
DuroMax doesn't list parallel capability for either. Treat it as Unknown.
By Mike E. · Last checked October 16, 2026 · Based on manufacturer specs. Lines marked "Amazon only" are from Amazon, not the maker.