Get the Champion 4000W if:
- You have to lift it: 48.1 lb against 92.2 lb, with a carry handle.
- You want the smaller footprint: 17.9 x 11.7 x 19.7 in.
- 3,000W running covers what you plug in.
Inverter generators
The short answer
Our pick: Champion 4500W (201318)
500W more starting and running, a bigger tank with 14 hr at 1/4 load against 10, 3 dB(A) quieter, plus wheels and a power meter. The 4000 is the pick if you have to lift it: 48.1 lb against 92.2 lb.
Best for carrying
Best for more power and run time
Before you buy: Champion says the 4000 is "not recommended for emergency home backup". The 4500 listing is a set family; make sure you're on "4500W Gas Recoil Start", not the Remote Start or Dual Fuel sets, and note that reviews on that page mix all three. The 4000 listing also has a "4000W Dual Fuel" set; make sure you're on "4000W Gas". Both are gas-only models and non-returnable (hazmat).
As an Amazon Associate I earn from qualifying purchases.
Counted from the chart below: rows where one figure is clearly better. It's a tally, not an overall rating. The 1/4-load row counts for the 4500 because it runs longer while carrying the bigger load.
A green check means one figure is clearly better. No check means it's a tie, it's close, the makers measured it differently, or a figure is Unknown. Maker figures are used throughout; anything marked Amazon only comes from the Amazon listing, not the maker.
| 4000 | 4500 | Clearer | |
|---|---|---|---|
| Starting watts | 4,000W | 4,500W | 4500 |
| Running watts | 3,000W | 3,500W | 4500 |
| Fuel | Gasoline only | Gasoline only | |
| Engine | 149cc, variable speed | 212cc, variable speed | |
| Fuel tank | 1.54 gal | 2.25 gal (spec table) | |
| Run time at 1/4 load | 10 hr | 14 hr | 4500 |
| Run time at 1/2 load | Unknown | Unknown | |
| Noise (from 23 ft) | 64 dB(A) | 61 dB(A) | 4500 |
| TT-30R outlet | Yes, rated 25A | Yes, rated 29.2A | 4500 |
| Other outlets | 5-20R duplex, 12V DC, parallel outlets | 5-20R duplex (no GFCI), 12V DC, parallel outlets | |
| With parallel kit | Adds 120V 30A locking + 120V 50A RV outlets (kit model 100319 or 201248, per Champion's manual) | Kit sold separately (ParaLINK, per Champion) | |
| THD | Under 3% | Under 3% | |
| Parallel | With another Champion 4000W (kit sold separately); combined output Unknown | With any Champion inverter of 2,800W or more (ParaLINK, kit sold separately) | 4500 |
| CO shutoff | Yes (CO Shield) | Yes (CO Shield) | |
| Start | Recoil only; no battery | Recoil only (EZ Start Dial); no battery | |
| Display | No voltmeter | Intelligauge power meter (volts, Hz, hours) + fuel gauge | 4500 |
| Wheels | No (carry handle) | Yes, 5 in. solid, fold-down handle | 4500 |
| Weight | 48.1 lb | 92.2 lb | 4000 |
| Size (L x W x H) | 17.9 x 11.7 x 19.7 in | 23.2 x 17.7 x 20.1 in | 4000 |
| EPA / CARB | EPA certified; CARB Unknown | EPA certified; CARB Unknown | |
| Warranty | 3-year limited + lifetime tech support | 3-year limited + lifetime tech support |
Common things people plug in during an outage or at camp, checked against each generator's own gasoline ratings from the chart above: 4000 3,000W running and 4,000W starting, 4500 3,500W running and 4,500W starting. I used the top of each range, so a smaller appliance may do better. These are estimates, not test results.
| Load | Running watts | Starting watts | 4000 | 4500 |
|---|---|---|---|---|
| Full-size refrigerator | 150–400W | 800–1,200W | Yes | Yes |
| Freezer (chest or upright) | 100–500W | 500–1,000W | Yes | Yes |
| Sump pump, 1/3 HP | 500–800W | 1,000–1,600W | Yes | Yes |
| Sump pump, 1/2 HP | 800–1,050W | 1,300–2,150W | Yes | Yes |
| Gas furnace blower (1/2 HP fan) | 300–800W | 800–1,600W | Yes | Yes |
| Window AC, 5,000 BTU | 450–600W | 900–1,200W | Yes | Yes |
| Window AC, 10,000 BTU | 900–1,200W | 1,800–2,400W | Yes | Yes |
| RV rooftop AC, 13,500 BTU | 1,500–2,000W | 2,800–3,500W | One at a time | One at a time |
| CPAP (with heated humidifier) | 60–120W | No extra | Yes | Yes |
| Microwave | 600–1,200W | No extra | Yes | Yes |
| Coffee maker | 600–1,200W | No extra | Yes | Yes |
| Space heater (1,500W setting) | 750–1,500W | No extra | Yes | Yes |
| Well pump, 1 HP‡ | 1,000–2,000W | 2,000–4,000W | No | No |
| Circular saw, 7-1/4 in. | 1,200–1,800W | 2,400–3,600W | One at a time | One at a time |
| TV (32-55 in.) + router/modem | 90–420W | No extra | Yes | Yes |
| Phone/laptop charging | 20–100W | No extra | Yes | Yes |
| Electric water heater‡ | 3,000–4,500W | No extra | No | No |
‡ Check your well pump's and water heater's voltage. Neither Champion lists a 240V outlet, so anything that needs 240V is out on both.
Add up the running watts. Then take the one item with the biggest starting surge and add its starting watts to everything else's running watts. Both totals have to fit. Estimates.
Running: 400 + 800 + 75 + 20 = 1,295W (4000 43% of 3,000W · 4500 37% of 3,500W)
Biggest start: fridge starting 1,200 + everything else running 800 + 75 + 20 = 2,095W (4000 52% of 4,000W · 4500 47% of 4,500W)
4000 Yes4500 Yes
Running: 400 + 500 + 1,050 + 75 + 20 = 2,045W (4000 68% of 3,000W · 4500 58% of 3,500W)
Biggest start: 1/2 HP sump pump starting 2,150 + everything else running 400 + 500 + 75 + 20 = 3,145W (4000 79% of 4,000W · 4500 70% of 4,500W)
4000 Yes4500 Yes
Running: 2,000 + 600 + 150 + 100 = 2,850W (4000 95% of 3,000W · 4500 81% of 3,500W)
Biggest start: 13,500 BTU AC starting 3,500 + everything else running 600 + 150 + 100 = 4,350W (4000 109% of 4,000W · 4500 97% of 4,500W)
4000 No4500 Tight
These are typical figures. Check the label on your own appliance. It lists watts, or amps you can multiply by 120 to get watts.
Motors need starting watts. Fridges, freezers, pumps, furnace blowers and air conditioners pull a short surge each time they kick on, well above their running watts. Heaters, coffee makers and chargers don't.
Running several loads adds up. If two motors start in the same second, both surges stack. Start the big ones one at a time.
Load watts: Champion Power Equipment, Generator Wattage Chart. It covers appliances, not generators. Coffee maker range from Honda's wattage guide.
Both burn gasoline, so both put out carbon monoxide. Keep them outside, well away from doors, windows and vents. Both have Champion's CO Shield shutoff, but it's a backup, not a reason to run one in a garage.
Same TT-30R, same 12V outlet, same warranty. The 4500 trades 44 lb of extra weight for 500W more, longer run time, wheels and a power meter.
As an Amazon Associate I earn from qualifying purchases.
if you want wheels or a power meter. It has neither, and Champion lists no voltmeter.
if you have to lift it into a truck or RV bay. It weighs 92.2 lb.
Where the maker and the Amazon listing (or two maker documents) give different figures. This page uses the maker figure unless noted.
No. Champion rates it at 25A on the 4000 and 29.2A on the 4500.
Champion says the 4000 pairs with another 4000W. The 4500 pairs with any Champion inverter of 2,800W or more. Combined output for two 4000s is unconfirmed.
Not this one. The 201318 is gas only. Champion's dual fuel 4500W models are different products, and their propane figures don't apply here.
Champion doesn't state CARB status on either page, so this page doesn't claim it.
By Mike E. · Last checked October 16, 2026 · Based on manufacturer specs. Lines marked "Amazon only" are from Amazon, not the maker.